Wsw35; Max. Detection Period Of Dial Tone/Busy Tone During Recording Of Icm - Brother MFC640CW Service Manual

Hide thumbs Also See for MFC640CW:
Table of Contents

Advertisement

Selector
No.
1
Max. detection period of dial
|
tone/busy tone during recording of
4
ICM
5
|
Not used.
8
NOTE: Selectors 1 through 4 are applicable to models equipped with internal TADs.
Selectors 1 through 4: Max. detection period of dial tone/busy tone during recording of ICM
If the machine (called station) detects dial tone or busy tone exceeding the detection level specified
by selectors 1 through 3 of WSW30 for the period specified by these selectors, then it disconnects
the line.

WSW35

(Function setting 13)
Function
App. 4-38
Setting and Specifications
No. 1 2 3 4
0 0 0 0 :
0 0 0 1 :
0 0 1 0 :
0 1 0 0 :
|
1 1 1 1 :
No detection
1 sec.
2 sec.
4 sec.
|
15 sec.
Confidential