Selector
No.
1
Dial pulse generation mode
2
3
Break time length in pulse dialing
4
5
Inter-digit pause
6
Switching between pulse (DP) and
7
tone (PB) dialing, by the function
switch
Default dialing mode, pulse (DP)
8
or tone (PB) dialing

Selectors 1 and 2: Dial pulse generation mode

These selectors set the number of pulses to be generated in pulse dialing.
N:
Dialing "N" generates "N" pulses. (Dialing "0" generates 10 pulses.)
N + 1: Dialing "N" generates "N + 1" pulses.
10 - N: Dialing "N" generates "10 - N" pulses.

Selectors 3 and 4: Break time length in pulse dialing

These selectors set the break time length in pulse dialing.
(Example: If "1," "2," and "3" are dialed when N is set by selectors 1 and 2.)

Selectors 5 and 6: Inter-digit pause

These selectors set the inter-digit pause in pulse dialing.
(Example: If "1," "2," and "3" are dialed when N is set by selectors 1 and 2.)

WSW01

(Dial pulse setting)
Function
App. 4-2
Setting and Specifications
No. 1 2
0 0
:
N
0 1
:
N+1
1 0
:
10-N
1 1
:
N
No. 3 4
0 0
:
60 ms
0 1
:
67 ms
1 0
:
40 ms (for 16 PPS)
1 1
:
64 ms (at 106-ms intervals)
No. 5 6
0 0
:
800 ms
0 1
:
850 ms
1 0
:
950 ms
1 1
:
600 ms
0: Yes
0: PB
1:
No
1:
DP