Wsw10; Time Length From Transmission Of The Last Dial Digit To Cml On; Time Length From Cml On To Cng Transmission; Time Length From Cml On To Ced Transmission - Brother MFC640CW Service Manual

Hide thumbs Also See for MFC640CW:
Table of Contents

Advertisement

Selector
No.
1
Not used.
Time length from transmission
2
of the last dial digit to CML
ON
Time length from CML ON to
3
CNG transmission
Time length from CML ON to
CED transmission (except for
4
facsimile-to-telephone
switching)
5
No. of training retries
6
7
Encoding system
(Compression)
8
Selector 2:

Time length from transmission of the last dial digit to CML ON

This selector sets the time length from when the machine transmits the last dial digit until the CML
relay comes on.
Selector 3:

Time length from CML ON to CNG transmission

This selector sets the time length until the machine transmits a CNG after it turns on the CML relay.
Selector 4:

Time length from CML ON to CED transmission

This selector sets the time length until the machine transmits a CED after it turns on the CML relay.
This setting does not apply to switching between facsimile and telephone.
Selectors 5 and 6: No. of training retries
These selectors set the number of training retries to be repeated before automatic fallback.
Selectors 7 and 8: Encoding system (Compression)
This selector determines whether or not to allow the use of the MR/MMR coding system.

WSW10

(Protocol definition 2)
Function
MR
MMR
App. 4-13
Setting and Specifications
0: 100 ms
0: 2 sec.
0: 0.5 sec.
No. 5
6
0
0
:
1 time
0
1
:
2 times
1
0
:
3 times
1
1
:
4 times
0: Allowed
0: Allowed
1: 50 ms
1: 4 sec.
1: 2 sec.
1: Not allowed
1: Not allowed