Error Codes; Checksum - Mitsubishi Electric MR-J2S-*A series Instruction Manual

Melservo servo amplifiers and motors
Table of Contents

Advertisement

14. COMMUNICATION FUNCTIONS

14.5 Error codes

Error codes are used in the following cases and an error code of single-code length is transmitted.
On receipt of data from the master station, the slave station sends the error code corresponding to that
data to the master station.
The error code sent in upper case indicates that the servo is normal and the one in lower case indicates
that an alarm occurred.
Error code
Servo normal
Servo alarm
[A]
[a]
[B]
[b]
[C]
[c]
[D]
[d]
[E]
[e]
[F]
[f]

14.6 Checksum

Checksum range
The check sum is a JIS8-coded hexadecimal representing the lower two digits of the sum of JIS8-coded
hexadecimal numbers up to ETX, with the exception of the first control code (STX or S0H).
Error name
Normal operation
Data transmitted was processed properly.
Parity error
Parity error occurred in the transmitted data.
Checksum error
Checksum error occurred in the transmitted data.
Character not existing in the specifications was
Character error
transmitted.
Command not existing in the specifications was
Command error
transmitted.
Data No. not existing in the specifications was
Data No. error
transmitted.
Station number
or
group
STX or
SOH
(Example)
S
[0]
[A]
[1]
T
X
02H
30H
41H
31H
30H 41H 31H 32H 35H 46H 03H
152H
Lower 2 digits 52 is sent after conversion into ASCII code [5][2].
Description
ETX
Check
Checksum range
E
[2]
[5]
[F]
[5] [2]
T
X
32H
35H
46H
03H
14 - 8
Remarks
Positive response
Negative response