3. TROUBLESHOOTING

3. TROUBLESHOOTING

3.1 Communication error

If communication between the personal computer and the servo amplifier is suspended and the
communication error as shown in the following window occurs, check the code on the right of the error
message and remove its cause.
<Possible cause> Noise entry, hard disk fault, wiring fault, etc.
Code
001
Parity error occurred in the data sent from the personal computer.
002
Checksum error occurred in the data sent from the personal computer.
003
Character not given in the specifications was sent to the servo amplifier.
004
Command not given in the specifications was sent to the servo amplifier.
Data number not given in the specifications was sent to the servo amplifier.
005
Data outside the permissible range was sent to the servo amplifier.
None
Checksum error occurred in the data received by the personal computer.

3.2 Screen unprintable

If a screen is not printed after printing is started, open the Windows setup window and change the
display setting to 256 colors or less.