Chapter 6
Certification
Test
IEC 61000-4-11
IEC 61000-4-12
IEC 61000-4-16
IEC 61000-4-17
IEC 61000-4-18
IEC 61000-4-29
IEC 60255-5
a
Siemens-specified severity levels
EMC Immunity Type Tests per IEEE 1613
NOTE
The RUGGEDCOM RSG2100 meets Class 2 requirements for an all-fiber configuration and Class 1
requirements for copper ports. Class 1 allows for temporary communication loss, while Class 2 requires
error-free and interrupted communications.
ESD
44
Description
Voltage Dips
and Interrupts
Damped Oscillatory
Mains Frequency Voltage
Ripple on DC
Power Supply
Damped Oscillatory Wave
Voltage Dips
and Interrupts
Dielectric Strength
HV Impulse
Description
Enclosure Contact
Enclosure Air
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
AC and DC Power Ports
DC Power Ports
Slow Damped
2.5 kV Common Mode
DC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Test Levels
1000 A/m for 1 s
30% for 1 period
60% for 50 periods
100% for 5 periods
100% for 50 periods
2.5 kV Common
1 kV Differential
Mode @1 MHz
30 V Continuous
300 V for 1s
10%
on Power and Signal
1.0 kV Differential
Mode on Power
30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
2 kV (Fail-Safe
Relay Output)
2 kV
2 kV
5 kV (Fail-Safe
Relay Output)
5 kV
Test Levels
±2 kV
±4 kV
±8 kV
±4 kV
EMC and Environmental Type Tests
RUGGEDCOM RSG2100
Installation Guide
Severity Levels
3
4
3
3