FEED DOG HEIGHT
The highest position of the feed dog should be between 0.8 to 0.9 mm from the surface of the needle plate
when the pressure foot pressure adjusting lever is set at "3" and the presser foot is raised.
1. Set the pressure foot pressure adjusting lever at "3" and lower the presser foot.
2. Turn on the power switch.
3. Remove the bed cover (see page 3).
4. Turn the handwheel toward you to set the feed dog at the highest position.
5. Loosen the setscrew (A) and nut (B).
6. Adjust the feed dog height by turning the adjusting screw (C).
7. Tighten the nut (B) and setscrew (A).
Presser foot pressure
adjusting lever
MECHANICAL ADJUSTMENT
Presser foot
Feed dog
Setscrew (A)
Nut (B)
E (to raise)
D (to lower)
Adjusting screw (C)
13
0.80-0.90 mm
Surface of the
needle plate
MO200
5200QDC