Unit Dimensions - Lennox BCE3M*C SERIES Installation Instructions Manual

Table of Contents

Advertisement

Unit Dimensions

1 (25)
LINE VOLTAGE
INLETS
(Top and Left Side)
G
3-5/8
(92)
5 (102)
F
1-1/8
(29)
018
Dimension
in.
mm
A
38
965
B
15
381
C
22
559
D
13
330
E
14-1/2
368
F
8
203
G
5-5/8
143
H
12-3/4
324
J
20-3/8
518
Note: Unit is shipped configured for horizontal left-hand air discharge. Unit may be converted to horizontal right-hand air
discharge by repositioning horizontal drain pan.
Dimensions remain the same in all configurations.
Page 2 of 23
1 (25)
SUPPLY AIR
OPENING
E
D
1 (25)
LOW VOLTAGE
(Top and Right Side)
TOP VIEW
B
CIRCUIT
BREAKER
COVER
AIR FLOW
SUCTION
LINE
LIQUID
LINE
1-1/8
H
(29)
OPENING
FRONT VIEW
024
in.
mm
40-1/2
1029
18-1/2
470
22
559
16-1/2
419
14-1/2
368
8
203
5-5/8
143
16-1/4
413
20-3/8
518
INLETS
3/4 (19)
LINE VOLTAGE INLETS
(Top and Right Side)
LOW VOLTAGE INLETS
(Either Side)
A
CONDENSATE DRAIN
PIPING PLATE (4)
(2-1/4 x 3-3/4)
FILTER ACCESS
1/2
(13)
030
in.
mm
in.
43
1092
52-1/2
18-1/2
470
21-7/8
22
559
22
16-1/2
419
19-7/8
14-1/2
368
14-1/2
8
203
8
5-5/8
143
5-5/8
16-1/4
413
19-5/8
20-3/8
518
20-3/8
Issue 1720
C
J
OPENING
SIDE VIEW
036
042
mm
in.
mm
1334
48
1219
556
21-7/8
556
559
26-1/4
667
505
19-7/8
505
368
18-3/4
476
203
9-1/4
235
143
4-1/2
114
498
19-5/8
498
518
24-5/8
625
1-1/8
(29)
048/060
in.
mm
52-1/2
1334
21-7/8
556
26-1/4
667
19-7/8
505
18-3/4
476
9-1/4
235
4-1/2
114
19-5/8
498
24-5/8
625
507621-01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bcs3m*c series

Table of Contents