RMDX21, RMDX25
6.3
Making air inlet and outlet vents
I
NOTE
At high ambient temperatures, the refrigerator can only provide its
maximum cooling capacity if the optimum ventilation has been
provided.
➤ Make a cut out in the wall to fit an appropriate upper and lower vent
system, choose LS300 check the dimensions required for the vent. See
chapter "Preparing the installation" on page 22.
If the lower ventilation grille cannot be installed flush with the floor, you will
need to provide a vent hole though the floor. This hole must be at lest 40 mm
diameter or larger:
➤ Make an air inlet vent in the floor (fig. 2 4, page 2) behind the refrigerator
near the gas burner.
➤ Shield the end of the opening with a deflector to prevent sludge or dirt
from getting inside while driving (fig. 8, page 5).
If you have to use a roof vent instead of an upper wall vent:
➤ Cut out a section in the roof. Refer to the roof vent instruction manual for
the required dimensions. When doing so, observe the information, see
chapter "Preparing the installation" on page 22.
EN
Installing the refrigerator
25