I/O Signal When Cc-Link Ver.2 Double Setting Is Selected (Pr. 544 = 12) - Mitsubishi Electric FR-A7NC Instruction Manual

Plug-in option
Hide thumbs Also See for FR-A7NC:
Table of Contents

Advertisement

I/O SIGNAL LIST
6.2.3

I/O signal when CC-Link Ver.2 double setting is selected (Pr. 544 = 12)

(1) Remote I/O (32 points)
Same as when Pr. 544 = 0 (
(2) Remote register
Description
Address
Upper 8 Bits
RWwn
Monitor code 2
Set frequency (0.01Hz increments) /
RWwn+1
torque command *
Link parameter
RWwn+2
extended setting
RWwn+3
RWwn+4
Monitor code 3
RWwn+5
Monitor code 4
RWwn+6
Monitor code 5
RWwn+7
Monitor code 6
("n" indicates a value determined according to the station number setting.)
*
For the FR-A700 series, setting "3" or "5" in Pr.804 during torque control under Real sensorless vector control or
vector control sets torque command in RWwn + 1.
50
Refer to page 46)
Refer
Lower 8 Bits
Page
Monitor code 1
Instruction code
Write data
to
Address
Upper 8 Bits
63
RWrn
63
RWrn+1
64
RWrn+2
Reply code 2
64
RWrn+3
64
RWrn+4
64
RWrn+5
64
RWrn+6
64
RWrn+7
Description
Lower 8 Bits
First monitor value
Second monitor value
Reply code 1
Read data
Third monitor value
Fourth monitor value
Fifth monitor value
Sixth monitor value
Refer
to
Page
67
67
67
67
68
68
68
68