Plumbing Manifold; Connections - Worcester Greenstar CDi Compact Installation, Commissioning And Servicing Instructions

Wall hung rsf gas fired condensing combination boiler
Table of Contents

Advertisement

PRE-INSTALLATION
Radius 600mm
Fig. 14 Bathroom installations
3.7

PLUMBING MANIFOLD

3.7.1 CONNECTIONS

Heating System
22mm compression fittings
DHW
15mm compression fittings
Gas
22mm compression fittings
Use the fittings supplied in the Hardware literature pack.
Further guidance on pipe routing can be found printed
on the boiler template (supplied with the boiler).
• For further ease of fitting, an optional Vertical Pre-piping Assembly kit
is available, comprising four pre-formed copper water pipes.
Part number: 7 716 192 713.
• To cover the pipe work under the boiler, down to the counter top, an
optional Worcester accessory the Below Boiler Pipe Cover can be
used, Part number: 7 716 192 608.
1 2
3
4
Fig. 15 Pipe dimensions
14
6720646608-124.2Wo
5 6
7
2
3
1
2
3
Fig. 16 Plumbing manifold
No. Function
1
Condensate drain
2
CH Flow
3
DHW Outlet
4
Gas
5
DCW Mains In
6
PRV drain
7
CH Return
Table 7 Key to figures 15 & 16
5
7
4
5
6
7
From left
Diameter of
case edge
pipe
33mm
22mm
65mm
22mm
130mm
15mm
195mm
22mm
260mm
15mm
291mm
15mm
325mm
22mm
6 720 803 800 (2012/11)