Pre-Installation
NOTICE:
Damage to appliance:
Contaminated combustion air.
▶ Do not use any cleaners containing chlorine or hydrogen halide (i.e.
spray cans, primers, cleaners, paint and glue).
▶ Do not store or use these substances in the appliance, room.
▶ Avoid the build up of dust.
NOTICE:
Damage to appliance:
Extreme temperatures may cause damage to the heating system.
▶ Ensure the ambient temperature is above 0 °C and below 35 °C.
NOTICE:
Damage to system:
The heating system pipe work can be damaged by frost if installed in an
internal unheated area, such as a loft, basement or garage.
The appliance internal frost protection only monitors the system water
temperature within the appliance to provide protection for the
appliance.
▶ Install a frost thermostat and pipe thermostat connected in series, to
protect the system pipe work.
We recommend that the frost thermostat is sited in the coldest
unheated area in which pipe work is located and that it is set to call for
heat at 5 °C. The Pipe stat should be located on whichever pipe is
furthest from the heated area where warmer water will be drawn from
considering the direction of flow, and set to end the demand at 15 °C.
▶ The system pipe work in the internal unheated area should be
insulated.
▶ If the appliance is to be shut down for an extended period, drain the
central heating system.
The appliance must be installed where:
▶ The area is well lit, allowing to clearly see the appliance to carry out
any work or checks.
▶ An engineer can gain clear and safe access to work on the product or
component, including making adequate provision for visual
inspection of flues in voids.
▶ The homeowner can gain clear and safe access to the controls, check,
top up or reset the appliance.
▶ Roof space installations must fully conform to BS 5410 part 1: roof
space installations.
▶ Products in roof spaces must have permanent fixed lighting, a
permanent fixed retractable ladder and a fixed floor area sufficient to
allow access for normal use and servicing around the product and
between and the access hatch.
We would also recommend that a remote pressure gauge and filling
loop are sited where the customer can gain easy access for checking
and topping up.
14
4.3.2

Rooms containing a bath or shower

CAUTION:
Risk of electric shock
▶ Any switch or appliance control using mains electricity must not be
within reach of a person using the bath or shower.
• In all cases the installation must be in accordance with the latest
amendments to the latest edition of the IET Wiring Regulations
(BS7671).
• Check the IP rating of any control units to be used on this appliance.
• Circuit breaking appliances should be used in accordance with the
regulations.
• Figure 12 is for guidance only.
A
Fig. 12 Bathroom installations
[1]
Zone 1
[2]
Zone 2
[2*] Without the end wall, zone 2 must extend 600mm from the bath
[A]
600mm radius from the bath or shower
4.3.3

Plumbing manifold

Connections
Heating System: 22mm compression fittings
Gas: 22mm compression fittings
Use the fittings supplied in the Hardware pack.
1. CH Flow 22 mm
2. Mains Gas Supply 22 mm
3. CH Return 22 mm
Pre-plumbing
With the plumbing manifold installed, pipe work can be installed to the
valves on the manifold.
The pipes can be run below the boiler or alternatively up behind the
boiler.
Running pipes behind the boiler
If the boiler pipes are to be run behind the appliance ensure that the
pipes pass close to the wall as shown in the diagram opposite, and within
the pipe guide.
Greenstar 8000 Life – 6720883866 (2019/04)
A
A
0010017086-001