Mitsubishi MELSEC FX3U Series Handbook page 49

Hide thumbs Also See for MELSEC FX3U Series:
Table of Contents

Advertisement

Device name
High-speed
1-phase 1-count input
counter
1-phase 2-count input
2-phase 2-count input
Contact
Coil
Current value
Data register
For general use
*1
For keep
For special use
File register
Index register
16-bit Z device
16-bit V device
32-bit Z device (at
modification of direct value)
Extension register
Extension file register
Pointer
Normal pointer
END pointer
Interrupt
Input interrupt (delay
*3
pointer
interrupt)
Timer interrupt
Counter interrupt
Module access device
Decimal constant
Hexadecimal constant
Real constant
Character string constant
*1 When the latch range of the device for keep of the FX3 Series is changed, the latch range must be changed.
*2 Set the parameter at [Parameter] →[FX5UCPU] → [CPU Parameter] → [Memory/Device Setting] → "Option Battery Setting" in [Device/
Label Memory Area Setting].
*3 Set the interrupt setting by the parameter accordingly.
*4 The parameter is reflected at [Parameter] → [FX5UCPU] → [Module Parameter] → [High Speed I/O] → [Input Function] → [General/
Interrupt/Pulse Catch]. Also, the parameter is reflected to [Module Parameter]→[Input Response Time].
*5 The parameter is reflected at [Parameter] → [FX5UCPU] → [CPU Parameter] → [Interrupt Settings] → [Fixed Interval Setting].
FX3U/FX3UC
After replacing to
MELSEC iQ-F
C235 to C245
C235 to C245
C246 to C250
C246 to C250
C251 to C255
C251 to C255
CS235 to CS255
CS235 to CS255
CC235 to CC255
CC235 to CC255
CN235 to CN255
CN235 to CN255
D0 to D199
D0 to D199
D200 to D7999
D200 to D7999
D8000 to D8511
SD0 to SD8511
File register
D1000 to D7999
Z0 to Z7
Z0 to Z7
V0 to V7
Z10 to Z17
Z0 to Z7
Z0 to Z7
R0 to R32767
R0 to R32767
ER0 to ER32767
P0 to P4095 (except P63)
P0 to P4095 (except P63)
P63
GOEND
I00
I0 to I15
I10
I20
I30
I40
I50
I6
I28 to I31
I7
I8
I010
I16 to I21
I020
I030
I040
I050
I060
Module number (0 to 7)
Module number (0 to 15)
BFM number (0 to 32766)
BFM number (0 to 65535)
16-bit: K-32,768 to K32,767
16-bit: K-32,768 to K32,767
32-bit: K-2,147,483,648 to
32-bit: K-2,147,483,648 to
K2,147,483,647
K2,147,483,647
16-Bit: H0 to HFFFF
16-Bit: H0 to HFFFF
32-Bit: H0 to HFFFFFFFF
32-Bit: H0 to HFFFFFFFF
128
-126
-1.0×2
to -1.0×2
, 0,
-1.0×2
-126
128
1.0×2
to 1.0×2
1.0×2
32 single-byte characters
255 single-byte characters
Precautions
Setting of the FX3 Series compatibility
assignment and replacement of the device
number are necessary by the parameter.
(Refer to Page 49 Precautions when
Using the High-speed Counters)
Refer to Page 48 SM/SD Device
Replacement.
Substitution is possible by using the
device initial value function.
If necessary, replace the direct value
modification to the LZ device.
The battery mode setting is necessary.
Replaced to OUT SM4095
Replaced as follows.
I00→I0
I10→I1
I20→I2
I30→I3
I40→I4
I50→I5
=1: Rise interrupt
=0: Fall interrupt
When  is 2 to 9, it will be replaced with
P4095.
Replaced as follows.
I6→I28
I7→I29
I8→I30
=1 to 99: Timer value
Replaced as follows.
I010→I16
I020→I17
I030→I18
I040→I19
I050→I20
I060→I21
The module number will be replaced
increasing by +2.
128
-126
to -1.0×2
, 0.
-126
128
to 1.0×2
4 Conversion of the Projects
4.2 Precautions when Converting the Projects
4
*2
*4
*5
47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec fx3uc seriesMelsec iq-f series