Extension device
Device name
Model name
Extension device
FX2NC-1HC
FX3UC-4AD
FX2N-5A
FX2N-2AD
FX2N-8AD
FX2N-2LC
FX2N-2DA
FX2N-1HC
FX2N-10PG
FX3U-20SSC-H
FX2N-232IF
FX2N-32CCL
FX2N-64CL-M
FX3U-ENET
FX3U-64DP-M
FX3U-32DP
FX3U-CAN
FX3U-J1939
FX2N-10GM
FX2N-20GM
FX2N-1RM-SET(-E)
FX2N-32DP-IF(-D)
FX2N-64DNET
Expansion adapter
FX3U-232ADP(-MB)
FX3U-485ADP(-MB)
FX3U-ENET-ADP
FX3U-3A-ADP
FX3U-4AD-ADP
FX3U-4DA-ADP
FX3U-4AD-PT-ADP
FX3U-4AD-PTW-ADP
FX3U-4AD-PNK-ADP
FX3U-4AD-TC-ADP
FX3U-CF-ADP
3 Replacement from FX3UC to FX5UC
28
3.3 Selection of Substitute Models
Recommended Substitute Models
Model name
*1
FX3U-2HC
*1
FX3U-4AD
*1
FX3U-4AD+FX3U-4DA
*1
FX3U-4AD
FX5-8AD
FX5-4LC
*1
FX3U-4DA
*1
FX3U-2HC
*1
FX3U-1PG
FX5-40SSC-S
No recommended substitute models
FX5-CCL-MS
No recommended substitute models
No recommended substitute models
No recommended substitute models
No recommended substitute models
No recommended substitute models
No recommended substitute models
FX5-20PG-P
FX5-20PG-P
No recommended substitute models
No recommended substitute models
No recommended substitute models
FX5-232ADP
FX5-485ADP
No recommended substitute models
FX5-4AD-ADP+FX5-4DA-ADP
FX5-4AD-ADP
FX5-4DA-ADP
FX5-4AD-PT-ADP
No recommended substitute models
No recommended substitute models
FX5-4AD-TC-ADP
No recommended substitute models
Special notes
The European terminal block must be replaced to
the 40-pin connector.
The wiring must be replaced from the European
terminal block to the screw terminal block.
The wiring must be replaced from the screw
terminal block to the spring clamp terminal block.
The wiring must be replaced from the screw
terminal block to the spring clamp terminal block.
Replacement of the wiring from the screw terminal
block to the connector is necessary.
The open collector output is up to 200 kpps in the
recommended substitute models.
Replacement of the wiring from connector to
terminal block is necessary.
Replacement is necessary due to the difference of
the connector type for external input connection.
Set to the intelligent device station in the
*2
recommended substitute models.
Ethernet port is built into FX5UC CPU module.
It cannot be used alone.
Replacement is necessary due to the difference of
the connector type.
It cannot be used alone.
Replacement is necessary due to the difference of
the connector type.
Ethernet port is built into FX5UC CPU module.