Data Carrier Installation
Mounting in a Metal
Casing
Effect of Misalignment
The V600-D2KR16 can be either surface-mounted or flush-mounted in a metal
casing. If mounted as shown in the following diagrams, there will be no effect on
the transmission range.
Flush-mounted
10 mm min.
Data carrier
Metal casing
Flush-mounted in metal casing
Note When the special-purpose holder is used, this becomes 9 mm max.
The transmission range will be reduced if the R/W Head does not face the DC
directly when data is transmitted. Try to keep any misalignment below 10°, as
shown in the following diagram.
Correct
DC
Read/Write Head
Surface-mounted
10 mm min.
5 mm max.
(See note.)
Surface-mounted on metal
Incorrect
DC
Read/Write Head
Section
4-2
Data carrier
Metal casing
This angle should
θ
not exceed 10°.