Transmission Time
TAT (Reference)
Transmission Time With the Data Carrier (Reference)
18
The following diagram shows the TAT and lower-level transmission time for the
READ command.
RDH1.
The following diagrams show the TAT and lower-level transmission time for
V600-CA1A, V600-CA2A, V600-CD1D-V2, and V600-CF1A Serial Interface ID
Controllers. (The TAT for Parallel Interface ID Controllers and ID Sensor Units
varies with the host's software.)
Calculation Method (Reference)
Read/Write
Read
Write
N: Number of bytes processed
Note
1. The value given for the TAT data assumes that the communications settings
for the V600-CA1A ID Controller are as follows:
Baud rate: 9600 bps; data length: 8 bits; stop bits: 1; parity: odd.
2. The number of bytes is the number for ASCII code. (For details, refer to the
RFID System Operation Manual (Z83).
* ↵
. . . . . .
Lower-level
transmission time
Turn-around time (TAT)
(Auto) write
Number of bytes processed
T = 2.9N + 69.8
T = 5.3N + 105.6
(Auto) write
Number of bytes processed
Section
* ↵
RD001122
. . .
(Auto) read
(Unit: ms)
TAT
(Auto) read