Transmission Range; Transmission Range Specifications (Certified Performance) - Omron V600-CA1A Operation Manual

V600 series r/w heads and sram data carriers
Table of Contents

Advertisement

Transmission Range

3-1

Transmission Range

3-1-1 Transmission Range Specifications (Certified Performance)

R/W Head
Setting conditions
V600-H07
Stationary
Moving
V600-H11
Stationary
Moving
1) V600-D8KR12, V600-D8KR13 Data Carriers
2) V600-D8KR04 Data
Carriers
3) V600-D2KR16 Data Carriers
16
Flush-mounted within metal 10 to 50
Surface-mounted on metal
Flush-mounted within metal 25 to 50
Surface-mounted on metal
Flush-mounted within metal 5 to 40
Surface-mounted on metal
Flush-mounted within metal 25 to 40
Surface-mounted on metal
Note
1. These specifications are the certified performance when taking into consid-
eration variations in ambient temperatures and products.
2. The read range and the write range are the same.
3. The Data Carrier and Read/Write Head installation conditions are as fol-
lows:
Read/Write Head
Steel
For flush-mounting within metal, the read/write distance changes depending on
distance x from the metal.
x mm
Flush-mounted
Flush-mounted within metal
10 mm min.
Flush-mounted within metal
For details regarding R/W Head and DC installation, refer to Section 4 Installa-
tion.
Transmission range (unit: mm, axis slip: ±10 mm)
V600-D8KR12 V600-D8KR13 V600-D8KR04 V600-D2KR16
10 to 30
10 to 60
10 to 35
20 to 30
25 to 60
20 to 35
10 to 30
5 to 45
10 to 30
15 to 30
25 to 45
15 to 30
Data carrier
Metal
Surface-mounted on metal
x mm
20 mm max.
Metal
10 mm min.
Data carrier
5 mm max.
Metal
(see note)
Section
See page 28.
---
10 to 100
---
See page 28.
---
50 to 100
---
See page 28.
2 to 15
10 to 65
2 to 15
See page 28.
6 to 15
30 to 65
10 to 15
Metal
Flush-mounted within metal
Surface-mounted
Metal
Surface-mounted on metal
Data carrier
Metal
Surface-mounted on metal
3-1