Online/Device
Setup/Process
Variables
Online/Device
Setup/Device Status
Page 136
Displays a gauge meter representation of the current
PV Meter
value of the Primary Variable (pressure input)
Displays the current value of the Primary Variable
PV
(pressure input) in user selected engineering units
Displays a trending chart of the current value of the
Trend of PV
Primary Variable (pressure input)
Displays a gauge meter representation of the current
SV Meter
value of the Secondary Variable (meter body
temperature)
Displays the current value of the Secondary Variable
SV
(meter body temperature) in user selected engineering
units
Displays a trending chart of the current value of the
Trend of SV
Secondary Variable (meter body temperature)
Displays a gauge meter representation of the current
TV Meter
value of the Tertiary Variable (static pressure)
Displays the current value of the Tertiary Variable (static
TV
pressure) in psi
Displays a trending chart of the current value of the
Trend of TV
Tertiary Variable (static pressure)
Displays a gauge meter representation of the current
ET Meter
value of the Electronics Temperature
Displays the current value of Electronics Temperature in
ET
degrees C
Displays a trending chart of the current value of the
Trend of ET
Electronics Temperature
Displays a gauge meter representation of the current
AO Meter
value of the Analog Output
Displays a trending chart of the current value of the
Trend of AO
Analog Output
Displays a bar graph of the current value of the Analog
PV AO %
Output
PV % rnge
Displays the current value of transmitter Output in %
Displays a pictorial representation of the current device
Overall Status
status
Displays all possible Critical Status faults and indicates
Critical
OFF for inactive faults or ON for active faults.
Help – Critical
Provides a more detailed description of each Critical
Diagnostics
Status fault
Displays the first set of possible Non-Critical Status
Non-Critical
faults and indicates OFF for inactive faults or ON for
active faults.
Help – Non-
Provides a more detailed description of each of the first
Critical
set of Non-Critical Status faults
Diagnostics
Displays the second set of possible Non-Critical Status
Non-Critical
faults and indicates OFF for inactive faults or ON for
active faults.
Help – Non-
Provides a more detailed description of each of the
Critical
second set of Non-Critical Status faults
Diagnostics
Displays all possible Extended Device Status faults and
Ext dev status
indicates OFF for inactive faults or ON for active faults.
Displays an advanced diagnostic detailed breakdown of
Additional Status
all Critical and Non-Critical faults