2801 - Pms Setup - NEC 28i System Manual

I-series
Hide thumbs Also See for 28i System:
Table of Contents

Advertisement

Description
Use Program 2801 - PMS Setup to assign an LAPBU PCB (P/N
92156) circuit and the DCI software port for PMS. You must have an
LAPBU PCB installed to use PMS Integration features. This program
has two prompts:
Modem No. - which designates the LAPBU PCB for PMS
Integration
DCI No. - which designates the software port number for the DCI
port connected to the PMS system. You should not use the PMS
DCI for SMDR or system reports.
Conditions
None
Default Setting
The LAPBU PCB is not assigned (Modem No. = 0).
The PMS DCI software port is not assigned (DCI No. = 0).
Feature Cross Reference
PMS Integration
Telephone Programming Instructions
To enter data for Program 2801 (PMS Setup):
1. Enter the programming mode.
2. 2801 + HOLD.
Modem No:
The previously programmed value displays.
3. Enter the number of the LAPBU PCB (normally 1) + HOLD
DCI No:
The previously programmed value displays.
4. Enter the software port number for the DCI port connected to the
PMS system.
5. HOLD to exit.