General Operating Parts; Fuel Specifi Cations; Good Faith Wall Surface/Tv Guidelines - Heat & Glo ST-36TR-IFT Owner's Manual

Hide thumbs Also See for ST-36TR-IFT:
Table of Contents

Advertisement

B. General Operating Parts
Figure 3.2 references the general operating parts of the
appliance and the section of this manual in which they are
discussed.
DECORATIVE DOORS
(NOT SHOWN)
SECTION 4.B.
FAN KIT
SECTION 3.H & SECTION 3.J
CLEAR SPACE
SECTION 3.A.
Figure 3.2 General Operating Parts
C. Fuel Specifi cations
WARNING! Risk of Fire or Explosion! Appliance must
be set up for compatible gas type!
• This appliance is designed to operate on either natural
gas or propane. Make sure the appliance is compatible
with gas type selected for installation site.
• Conversions must be made by a qualified service
technician using Hearth & Home Technologies specifi ed
and approved parts.
8
FIXED GLASS ASSEMBLY
(NOT SHOWN)
SECTION 4.B.
MANTEL
HEARTH
CONTROL CAVITY
SECTION 3.I
Heat & Glo • ST-36TR-IFT, PIER-36TR-IFT Owner's Manual • 2482-981 Rev. B • 3/17
D. Good Faith Wall Surface/TV Guidelines
FIREPLACE
OPENING
Figure 3.3. Good Faith Wall Surface Temperatures Above Appliance
NOTICE: Temperatures listed above are taken with a
temperature measuring probe as prescribed by the test
standard used for appliance certifi cation. Temperatures
on walls or mantels taken with an infrared thermometer
may yield increased temperatures of up to 30 degrees or
more depending on the thermometer settings and material
characteristics being measured.
TO CEILING
90°F
90°F
95°F
95°F
48 in.
42 in.
100°F
36 in.
110°F
30 in.
120°F
24 in.
18 in.
130°F
12 in.
6 in.
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
APPLIANCE FRONT