Output Voltage Gain

•Changes the Inverter output voltage, based on the voltage selected in AVR voltage selection A082
as 100%.
•You can avoid motor hunting by reducing the output voltage gain.
Parameter No.
Function name
A045
Output voltage gain
Related functions
DC Injection Braking
•DC injection braking is applied to the motor depending on the motor load.
•Two methods are available for DC injection braking: One is the external method via the multi-
function input terminal; the other is the internal method performed automatically to start/stop the
motor.
Even if DC injection braking is used, however, the motor may not stop depending on the moment
of inertia of the motor load.
Parameter No.
Function name
DC injection braking
A051
selection
DC injection braking
A052
frequency
DC injection braking
A053
delay time
A054
DC injection braking power
A055
DC injection braking time
DC injection braking
A056
method selection
Startup DC injection
A057
braking power
Startup DC injection
A058
braking time
DC injection braking
A059
carrier frequency
Related functions
Data
20 to 100
AVR voltage
selection
(A082)
A045
Base frequency
(A003/A203/A303)
00: OFF (Disabled)
01: ON (Enabled)
02: ON (FQ) (Frequency control [A052
set value])
0.00 to 400.00
0.0 to 5.0
0 to 100 (0.4 to 55 kW)
0 to 80 (75 to 132 kW)
0.0 to 60.0
00: Edge operation
01: Level operation
0 to 100 (0.4 to 55 kW)
0 to 80 (75 to 132 kW)
0.0 to 60.0
0.5 to 15.0 (0.4 to 55 kW)
0.5 to 10.0 (75 to 132 kW)
4-2 Function Mode
Default setting
100
A082
Max. frequency
(A004/A204/A304)
Data
Default setting
C001 to C008
Unit
%
Unit
00
0.50
Hz
0.0
s
50
%
40
0.5
s
01
0
%
0
0.0
s
5.0
Hz
3.0
4-24
4