Language; Enter Alt-Azi Mode (Or Enter Eq Mode); Electric Focuser; Pec Option - iOptron iEQ30 Pro Instruction Manual

Equatorial mount
Hide thumbs Also See for iEQ30 Pro:
Table of Contents

Advertisement

5.4.11. Language

Select one of supported language.

5.4.12. Enter Alt-Azi Mode (or Enter EQ Mode)

Switch the iEQ30 Pro operation between EQ and AA modes.

5.5. Electric Focuser

This function controls an iOptron electric focuser.

5.6. PEC Option

You can turn "PEC Playback On" to improve tracking accuracy which is especially useful for
long exposure astrophotography. The default status is "PEC Playback Off" when the mount is turned
on.

5.6.1. Record PEC

All equatorial mounts have a small variation in the worm gears which may be corrected by using
Period Error Correction or PEC. PEC is a system which improves the tracking accuracy of the mount by
compensating for variations in the worm gear and is especially useful when doing astrophotography
without autoguiding. Because the variations are regular, it is possible to record the corrections required
to cancel out the worm gear variations and to play them back to correct the periodic error caused by the
variations.
In order to use the PEC function, the Go2Nova
periodic error. The periodic error of the worm gear drive will be used to correct periodic error.
We recommend using a guiding camera to record the PE with autoguiding. Here's how to use
the PEC function:
1. Setup the mount with a telescope in autoguiding configuration by connecting a guiding
camera via the mount's Guide Port or using the ASCOM protocol;
2. Select "MENU=>Settings => Set Guiding Rates". Set a guiding speed from 0.10X to 0.90X.
The default setting is 0.25X;
3. Then press the BACK button and select "PEC Option" from the menu. Use the ▲ and ▼
scroll buttons to display the "Record PEC" option and press ENTER to start recording the periodic
error.
4. It takes the worm gear 480 seconds to make one complete revolution. After 480 seconds
PEC will automatically stop recording. The PEC value will be permanently stored inside PEC chip on
R.A. motor drive until a new data are recorded.
5. If you want to re-record the periodic error, select "Record PEC" and repeat the recording
processes again. The previously recorded information will be replaced with the current information.

5.6.2. PEC Data Integrity

This function will check the recorded PEC data integrity.

5.7. Park Telescope

This function parks the scope to one of four preset park positions.
®
hand controller first needs to record the
28

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents