3.5.1 OUTSIDE AIR - MOBILE HOME

Connection from the appliance's air intake to outside air is mandatory in mobile
homes only, either through a hole in the wall to line up with the knockout in the
pedestal back, or through a hole in the fl oor to line up with the hole in the
pedestal base. Use a fresh air kit. Secure the 4" (102mm) diameter aluminum
liner by fl aring the end once it is inserted through the 4 1/2" (114mm) diameter
hole in either the back or base of the pedestal. If the air intake is through the
fl oor, the hole in the pedestal back must be covered with sheet metal to avoid
cold air spillage into the room. A cover plate is available from your loca
authorized dealer/distributor. Avoid cutting away fl oor joists, wall studs, electrical
wires or plumbing. Seal around the outside pipe with insulation to prevent drafts.
Attach the rear knockout plate (located inside the ash pan for shipping purposes).
NOTE: The 1450 can only have outside air connected to pedestal backplate. Connection to bottom of
pedestal not available.
3.6

MOBILE HOME

THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/ROOF MUST BE
THE APPLIANCE MUST BE PROVIDED WITH OUTSIDE COMBUSTION AIR.
USE A CHIMNEY CERTIFIED FOR WOOD BURNING UL 103 S629, TYPE HT (2100°F).
MODEL 1100 IS APPROVED FOR INSTALLATION IN MOBILE HOMES IN THE UNITED STATES & CANADA.
MODELS 1400, 1400C, & 1450 ARE APPROVED FOR INSTALLATION IN MOBILE HOMES IN THE UNITED
STATES ONLY.
MODELS 1150 & 1900 ARE NOT APPROVED FOR INSTALLATION FOR MOBILE HOMES IN THE UNITED
STATES OR CANADA.
NOTE: All mobile home approved appliances must be secured to the fl oor of the mobile home except for
model 1150.
The pedestal base must be fi rmly bolted to the fl oor with 1/4 inch
lag bolts. For specifi c clearances, see "MINIMUM CLEARANCES
TO COMBUSTIBLES" section.
The appliance must be installed between ceiling joists, with
radiation shield and roof fl ashing, so that the structural strength,
insulation and waterproof qualities of the home are not lessened.
Seal with silicone to maintain a vapour barrier at the chimney and
outside air pipe penetrations.
WARNING
!
DO NOT INSTALL IN SLEEPING ROOM.
MAINTAINED.
THE APPLIANCE MUST BE BOLTED TO THE FLOOR.
INSTALL ACCORDING TO 24 CFR, PART 3280 (HUD).
KNOCKOUT
PLATE
TRIM
PEDESTAL
RAIN CAP
MOBILE HOME
ROOF FLASHING
RADIATION SHIELD
CEILING SUPPORT
TRIM COLLAR
APPLIANCE
BOLTED TO FLOOR
HEARTH PAD
OUTSIDE AIR CONNECTION
THROUGH WALL OR FLOOR
W415-1468 / A / 09.30.16
11
EN
REMOVE TO
ALLOW FOR
TRANSPORATION