Floor Protection; Outside Air - Napoleon 1100PL Installation And Operating Instructions Manual

Epa wood burning stove
Table of Contents

Advertisement

10
3.4

FLOOR PROTECTION

If the appliance is to be installed on top of a combustible fl oor, it must be placed on an approved non-
combustible hearth pad, that extends 8" beyond the appliance sides and back and 18" to the front. The
reduced clearance from the back of the appliance may result in the appliance pad terminating shorter than 8"
beyond the appliance.
K
J
J
I
3.5

OUTSIDE AIR

IF ROOM AIR STARVATION OCCURS BECAUSE THE FRESH AIR INTAKE IS BLOCKED WITH ICE,
LEAVES, ETC., OR BECAUSE THE APPLIANCE DOOR WAS LEFT OPEN, OR DUE TO A STRONG
EXHAUST FAN OPERATING ETC., DANGEROUS FUMES AND SMOKE FROM THE OPERATING
The following are signs that a outside air kit may be required:
When there is combustion present: Wood burns poorly, smoke spills, back-draft takes place and your
chimney does not draw steadily.
In the winter there is too much condensation on the windows.
Opening a window seems to alleviate the above symptoms.
A ventilation system is installed in the house.
Other devices are present that exhaust house air.
The house has tight fi tting windows and/or is equipped with a well-sealed vapour barrier.
3.5.1
Connection from the appliance's air intake to the outside is
mandatory in mobile homes only, either through a hole in the
wall or through the hole in the fl oor to line up with the knock out
in the leg model or the hole in the pedestal base.
3.5.2
Use a fresh air kit. Secure the aluminum liner by fl aring the end
once it is inserted through the hole in the base of the leg or
pedestal model. If the air intake is through the fl oor, the hole in
the pedestal back must be covered with sheet metal to avoid
cold air spillage into the room. A cover plate is available from
your Wolf Steel Ltd. dealer. Avoid cutting away fl oor joists, wall
studs, electrical wires or plumbing. Seal around the outside pipe
with insulation to prevent drafts.
3.5.3
Attach the rear knockout plate (located inside the ash pan for
shipping purposes).
W415-0762 / A / 07.19.10
FRONT (I)
CANADA
USA
NOTE: If a section of horizontal chimney connector is used, fl oor protection is
required under the chimney connector and 2" beyond each side.
!
APPLIANCE COULD BE DRAWN INTO THE ROOM.
MINIMUM FLOOR PROTECTION
SIDES (J)
18"
8"
16"
8"
WARNING
BACK (K)
8"
8"

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1100c1400pl1400c

Table of Contents