Brother MFC7050C Service Manual page 112

Facsimile equipment
Hide thumbs Also See for MFC7050C:
Table of Contents

Advertisement

Selector
No.
1
Min. OFF time length of calling
signal (Ci)
2
3
Max. OFF time length of calling
signal (Ci)
4
5
Detecting time setting
6
7
Not used.
8
l
Selectors 1 through 4:
If the equipment detects the OFF state of calling signal (Ci) for a time length which is greater than the
value set by selectors 1 and 2 and less than the value set by selectors 3 and 4, it interprets the Ci
signal as OFF.
l
Selectors 5 and 6: Detecting time setting
These selectors set the time length required to make the equipment acknowledge itself to be called.
That is, if the equipment continuously detects calling signals with the frequency set by selectors 1
through 4 of WSW14 during the time length set by these selectors 5 and 6, it acknowledges the call.
WSW12
(Signal detection condition setting)
Function
Min. and max. OFF time length of calling signal (Ci)
V - 10
Setting and Specifications
No. 1
2
0
0
:
300 ms
0
1
:
500 ms
1
0
:
700 ms
1
1
:
900 ms
No. 3
4
0
0
:
6 sec.
0
1
:
7 sec.
1
0
:
9 sec.
1
1
:
11 sec.
No. 5
6
0
0
:
800 ms
0
1
:
200 ms
1
0
:
250 ms
1
1
:
150 ms
(in the U.S.A. and
Canadian versions)