installation
|
8

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS

Please read the section below carefully as clearances depend on whether the Airmate or the Rear Heat Deflector is installed on the stove.
Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the rear heat shield to a back wall.
Clearances may only be reduced by means approved by the regulatory authority.
Note: Minimum ceiling height roof exit - 83" (2108 mm)
ROOF EXIT
F
WALL EXIT
With 6"/152mm stainless steel flue and one piece of decro-mesh 900mm long perforate on the front and solid on the back.
with Airmate or
F3502B
Rear Deflector
Minimum Alcove Clearance to Combustible Materials
The Regency Freestanding models have been alcove approved and must be installed
with a listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height - 83" (2108 mm) Vertical Termination}
H = Maximum depth of alcove - 48" (1219mm)
G= Minimum width of alcove - 60" (1524mm)
8
| F3502B Freestanding Woodfire
C
A
D
A
B
250mm
150mm
NOTE:
NOTE:
ROOF EXIT
WALL EXIT
C
D
100mm
580mm
Be aware that local Codes and
Regulations may override some
clearances listed in this manual.
Check with your local inspector.
Clearances to combustibles are for
the safety of the property. To avoid
overheating and damaging the
appliance these clearances should
be maintained for non-combustibles
also.