MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS

Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the rear heat shield to a back wall.
Clearances may only be reduced by means approved by the regulatory authority.
Note: Minimum ceiling height roof exit - 2108 mm
ROOF EXIT
F
WALL EXIT
Residential Close Clearance (To be installed with required pipe components)
with Airmate or
F5102
Rear Deflector
Minimum Alcove Clearance to Combustible Materials
Note: Minimum alcove ceiling height - 2108 mm - Vertical Termination
H = Maximum depth of alcove - 1219mm
G= Minimum width of alcove - 1600mm
Flue Kit
Universal 7" (178mm) FLo-Met kit with 1 x 900mm decromesh (solid back) on top of appliance. an 8" (203mm) reducing to 7" (178mm) starting piece
of spigot need to be fitted to kit (If not supplied).
The flue pipe shall extend not less than 4.6 M above the top of the floor protector.
F5102 Regency Freestanding Wood Fire
C
A
D
A
B
305mm
203mm
NOTE:
NOTE:
ROOF EXIT
WALL EXIT
C
D
100mm
674mm
INSTALLATION
Be aware that local Codes and
Regulations may override some
clearances listed in this manual.
Check with your local inspector.
Clearances to combustibles are for
the safety of the property. To avoid
overheating and damaging the
appliance these clearances should
be maintained for non-combustibles
also.
E
381mm
469mm
A
ROOF EXIT
WALL EXIT
D
G
F