Location Limitations:
The product is designed to be installed indoors, in
a controlled environment. Air cooled models
discharge very warm air into the room. Water
cooled models discharge warm water into the
building's drain. Space needs to be provided for
service access.
Space Limitations
Do not block air flow at the front.
Airflow is in the front left and out the front right.
CU3030 also takes air in from below the cabinet.
Air Flow
Environmental Limitations
Air
temperature
Water
temperature
Water
pressure
Power supply – acceptable voltage ranges
115 volt model 104 volts
230 volt model 198 volts
Warranty Information
The warranty statement for this product is provided
separately from this manual. Refer to it for
applicable coverage. In general warranty covers
defects in material or workmanship. It does not
cover maintenance, corrections to installations, or
situations when the machine is operated in
circumstances that exceed the limitations printed
above.
Product Information
The product is a self contained cuber with bin. That
type of machine is designed to be free standing
can be built in under the counter.
May 2008
Page 2
Minimum
Maximum
o
o
50
F.
100
F.
o
o
40
F.
100
F.
20 psi
80 psi
Minimum
Maximum
126 volts
253 volts