Scotsman CU1526 Service Manual page 57

Hide thumbs Also See for CU1526:
Table of Contents

Advertisement

CU1526, CU2026, CU3030
Service Manual
Removal and Replacement
Purge valve
1. Remove left front grill.
2. Push and hold the Off button to shut the machine off.
3. Disconnect electrical power.
Electrical Shock
Hazard.
Disconnect electrical
power before
beginning removal
procedure.
4. Perform all procedures to remove the ice storage bin.
5. Unplug wires from valve coil.
Note: The coil can be removed from the valve body by rotating it 1/8 turn CW. After removal of the coil
the spring and plunger can be taken out.
6. Remove screws holding valve to mounting bracket.
7. Remove inlet and outlet hoses
8. Remove valve from cabinet.
9. Reverse to reassemble
Water level sensor
1. Switch the machine off.
2. Remove the top panel.
3. Locate water level sensor.
4. Squeeze the locking tabs together and pull the sensor up and out of the sump.
5. Unplug the electrical connection from the sensor.
6. Reverse to reassemble.