CU1526, CU2026, CU3030
Service Manual
Controller Information
Component Indicator Lights
•
Condenser Fan / Aux
•
Water Pump
•
Purge Valve
•
Water Solenoid
•
Hot Gas
•
Compressor
•
Ready to Harvest
•
Sump Empty
•
Sump Full
•
Curtain SW1
•
Curtain SW2
Component Indicator Light Table
System
Condenser Fan / AUX
Water Pump
Purge Valve
Inlet Water Solenoid Valve
Hot Gas
Compressor
Ready to Harvest
Sump Empty
Sump Full
Curtain Switch
Indicator Light ON
Fan Motor Powered
Pump Motor Powered
Purge Valve Opens
Not used this model
Hot Gas Valve Opens and harvest assist solenoid powered
Contactor Closes
Water contacting ice thickness sensor probe
Open between mid sensor and common
Closed between top probe and mid probe
Curtain open
May 2008