Control Switches - Scotsman CU1526 Service Manual

Hide thumbs Also See for CU1526:
Table of Contents

Advertisement

CU1526, CU2026, CU3030
Service Manual

Control Switches

There is a front on and off switch, located in the top
center of the louvers. Switching this switch Off will
immediately stop the machine. Switching it back on
will cause the machine to start in a timed harvest
cycle.
The controller also has on and off switches, which
can also switch the machine on and off, but their
operation is different:
To switch the machine OFF, push and release the
Off button. The machine will shut off at the end of
the next cycle. To shut the machine off
immediately, push and hold the Off button for 3
seconds.
To switch the machine ON, push and release the
On button. The machine will go through a start up
process and then resume ice making.
Note: Front On/Off Switch discontinued February
2012
Power Status
Water
Manual
Clean
Harvest
Code
Display
Control Operation - See Manual
Water Light On
- Restore water supply to
machine.
De-Scale Light On
- Clean and sanitize
machine.
Flush Setting
- To Change: Depress Off
for 3 seconds. Press On to select purge
(1-5) setting or A for Automatic.
Test Mode
- Depress Off for 3 seconds,
then depress Clean for 3 seconds.
Recall Diagnostic Codes
for 3 seconds. Press Harvest repeatedly
to go from most recent to oldest of 10.
Reset from Code 1, 2, 4 or 8
Off then Depress On.
02-4302-01
Note: A Component Indicator Light switches ON to
indicate that the component is operating.
Note: There are two Curtain Switch lights, SW1 and
SW2. These single plate models have one curtain
switch light on all the time, as a curtain switch light
is ON when a curtain is either open or not present.
February 2012
Page 12
De-scale
Sanitize
On
Off
Technician Section
Code
Description
F
. . . . . . . . . . Freeze Cycle
flashes . . . . Freeze Cycle is Pending
F
. . . . . . . . . . Harvest Cycle
H
flashes . . . . Manual Harvest
H
. . . . . . . . . . Bin is Full
b
. . . . . . . . . . Clean Cycle
C
. . . . . . . . . . Board Locked
L
. . . . . . . . . . Test Mode
d
. . . . . . . . . . Off
O
. . . . . . . . . . Self Test Failed
E
flashes. . . . Max Freeze - Retrying
1
. . . . . . . . . . . Max Freeze Time Shut Down
1
flashes . . . . Max Harvest - Retrying
2
. . . . . . . . . . Max Harvest Time Shut Down
2
. . . . . . . . . . Slow Water Fill
3
. . . . . . . . . . High Discharge Temp
4
. . . . . . . . . . Sump Temp Sensor Failure
5
. . . . . . . . . . Discharge Temp Sensor Failure
7
- Depress Off
flashes . . . Short Freeze - Retrying
8
Short Freeze - Thin ice
8 . . . . . . . . . . . .
All 4 Upper Lights Flashing
Locked Out - Contact Leasing Company
- Depress
Component Operation Indicator Lights
- Unit Remotely