STRATOS SYSTEM AVAILABLE CONFIGURATION / SET-UP

Integrated Scale on Single Cable Scanner

The following bar codes configure the scanner as to the current configuration of the
scale. The scale operation can be integrated into the software of Stratos. Presently, the scale
cannot be configured from the scanner. The scale is configured with a down load file/utility on
the PC. The following bar codes are to let the scanner know the configuration of the scale so it
can refute commands that do not make sense to the scale configuration, if needed.
Use the English Scale Defaults bar code to lay a template of
English mode operation into the scanner's memory. This will not
change scanner defaults. This bar code activates the scale in 4-
digit weigh mode (xx.yy lbs.), sets the scale to English mode, and
sets display required.
5-Digit Weight
1
4
1
0
1
0
For Metric mode operation, use the Metric Scale Defaults bar code.
It activates the scale in scanner memory in 5-digit weight mode,
sets the scale to Metric mode, and display required.
*No Scale
1
3
8
5
0
7
Scan the No Display bar code when no Metrologic remote display
is required with the scanner/scale.
©2004 Metrologic Instruments, Inc. All rights reserved
When it is desired to give the English mode weight in 5 digits (xx.yyy
lbs.), scan the 5-Digit Weight bar code after the English scale defaults
above.
When it is desired to remove the scale from the scanner's configuration
or the scale resides in a dual cable system, use the No Scale bar code.
The scanner will not attempt to communicate with the scale as a default
condition or after this bar code has been scanned.
70
English Scale Defaults
9
9
9
9
6
2
Metric Scale Defaults
9
9
9
9
6
1
No Display
1
4
0
9
0
2