SERVICING AND MAINTENANCE PROCEDURES
VERTICAL/HORIZONTAL SCAN MODULE – INSTALLATION
Operator must be properly grounded with wrist strap while performing this
Assembly Procedure
1. Blow off inside of unit and horizontal
engine assembly with ionized air gun.
2. With unit standing on the flange end,
grasp the horizontal engine with both
hands and insert the engine assembly
into the bottom base, aligning the blind
mate connector on the engine with the
mating connector on the bottom base.
3. Fasten
the
engine
M3x.5x8mm Torx screws. Tighten with
power driver and T-10 bit.
4. Rotate the rear of the vertical engine
base into the bottom case and slide the
engine forward to engage the front
flange.
Press the rear of the engine
against the bottom base.
5. Snap open the ZIF connector on the
vertical engine board and insert the
vertical engine ZIF cable with the blue
stiffener facing out. Fully seat the cable
and close the connector lock.
6. Fasten the vertical engine to the case
bottom with two (2) M3x.5x8mm Torx
screws. Tighten with Torx driver using a
T-10 bit.
7. If necessary, install horizontal, vertical
and rear cover plates and fasten with
M3x.5x6mm PH Phillips screws.