Electrical; Final Check List - Scotsman CME1356R User Manual

Modular ice cube machine
Hide thumbs Also See for CME1356R:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Electrical

All models must be installed with the correct wire size
and type per the Local Electric Code. Locate the
nameplate on the back of the cabinet and find the
numbers for Voltage, Phase, Minimum Circuit Ampacity
and Maximum Fuse Size. Either fuses or HACR type
circuit breakers may be used.
Electrical connections are made in the junction box in
the back of the cabinet.
The remote condenser is designed to be powered from
the ice machine. A separate knockout hole has been
provided in the ice maker electrical junction box.
1. Remove the junction box cover.
2. Knock out both holes for a field supplied strain relief.
3. Install wires and strain reliefs per code. Note:
Condenser fan motor wires are tagged.
4. Connect to wires and secure ground wire to ground
screw inside the junction box.
Conform to all applicable codes.
The electrical disconnect switch with fuse protection
must be a two pole type with a minimum of 3 mm
between open contacts.
After Utility Connections
1. Level the cabinet, use the leg levelers on the end of
the legs to adjust the cabinet height.
2. Wash out the bin. If desired, the interior of the bin
could be sanitized.
3. Locate the ice scoop (if supplied) and have it
available for use when needed.

Final Check List:

1. Is the unit located indoors in a controlled environment?
2. Is the unit located where it can receive adequate cooling air?
3. Has the correct electrical power been supplied to the
machine?
4. Have all the water supply connections been properly made?
5. Have all the drain connections been properly made?
6. Has the unit been leveled?
7. Have all unpacking materials been removed?
8. Has the bin control been installed?
9. Is the water pressure adequate?
10. Have the drain connections been checked for leaks?
11. Has the bin interior been wiped clean or sanitized?
12. Have any water filter cartridges been replaced?
10
Remote
Condenser Power
Connection
Power
Supply

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cme1056rCme1656r

Table of Contents