User response: Complete the following steps until the problem is solved:
1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80070101-0301ffff
Sensor [SensorElementName] Overtemp has transitioned from normal to non-critical state.
Explanation: The microprocessor 1 temperature has risen above its specified threshold.
May also be shown as 800701010301ffff or 0x800701010301ffff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 12
Automatically notify Support: No
User response: Complete the following steps until the problem is solved:
1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80070101-030201ff
Sensor [SensorElementName] has transitioned from normal to non-critical state.
Explanation: The temperature of microprocessor 2 has exceeded its specified threshold.
May also be shown as 80070101030201ff or 0x80070101030201ff
Severity: Warning
Alert Category: Warning - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0520
SNMP Trap ID: 12
Automatically notify Support: No
User response: Complete the following steps until the problem is solved:
1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
80070101-030202ff
Sensor [SensorElementName] has transitioned from normal to non-critical state.
Explanation: The temperature of microprocessor 2 has exceeded its specified threshold.
May also be shown as 80070101030202ff or 0x80070101030202ff
Severity: Warning
80070101-0301ffff • 80070101-030202ff
Chapter 6. Troubleshooting
255