General

WARNING
This prodcut contains a chemical known to the State
of California to cause cancer, birth defects, or other
reproductive harm.
CAUTION
SLP98DFV unit should not be installed in areas normally
subject to freezing temperatures.
These instructions are intended as a general guide and do
not supersede local codes in any way. Consult authorities
having jurisdiction before installation.
In addition to the requirements outlined previously, the
following general recommendations must be considered
when installing a SLP98DFV furnace:
Place the furnace as close to the center of the air
distribution system as possible. The furnace should
also be located close to the chimney or vent termi-
nation point.
When the furnace is installed in an attic or other
insulated space, keep insulation away from the fur-
nace.
When the furnace is installed in an unconditioned
space, consider provisions required to prevent
freezing of condensate drain system.
Back
NOTE - Do not install the furnace on its front, back or in the horizontal position

Installation - Setting Equipment

Do not install the furnace on its front, back or in the
horizontal position. See figure 5. Do not connect the
return air ducts to the back of the furnace. Doing so
will adversely affect the operation of the safety control
devices, which could result in personal injury or death.
Select a location that allows for the required clearances
that are listed on the unit nameplate. Also consider gas
supply connections, electrical supply, vent connection,
condensate trap and drain connections, and installation
and service clearances [24 inches (610 mm) at unit front].
The unit must be level from side to side. Unit may be posi-
tioned from level to 1/2" toward the front to aid in draining.
See figure 4.
AIR FLOW
FRONT VIEW
Unit must be level side-to-side. Unit may be positioned
from level to 1/2" toward the front to aid in draining.
Front
FIGURE 5
Page 6
WARNING
SETTING EQUIPMENT
AIR FLOW
SIDE VIEW
FIGURE 4
Horizontal
AIR FLOW
1/2"
max.
SIDE VIEW