Field Wiring Connections for Non-Communicating Thermostat Applications (Contiued)
DIP Switch Settings and On-Board Links (figure 47)
Thermostat
DIP Switch
Dual Fuel
DIP Switch 1
Single-Stage
Heat Pump
®
ComfortSense
7000 L7742U
thermostat w/
bilities
Capable of
2-stage gas
heat control
Dual Fuel
DIP Switch 1
Two Stage
Heat Pump
®
ComfortSense
7000 L7742U
thermostat w/
bilities
Capable of
2-stage gas
heat control
* Connect W1 to W1 ONLY if using defrost tempering kit 67M41.
NOTE - Do NOT make a wire connection between the room thermostat L terminal and the L terminal of the SLP98
integrated control.
W915
(Y1 to Y2)
Two-Stage
Cooling
Intact
OFF
Cut
OFF
TABLE 14
W914
(DS to R)
W951
(O to R)