Alignment Procedure of M123A Color TV
1. FLOWCHART OF ALIGNMENT PROCEDURE
B+
adjustment
Center & Amplitude and
OSD adjustment
2 Adjustment of B+ voltage
1) Apply 120VAC(±5V) to mains power input, and Philips standard testing pattern
to RF input.
2) Adjust VR830 in STANDARD mode until voltage at TP2 (B+) is 108V ±0.5V.
3. RF AGC adjustment
Observe monitor the collector waveform of Q101 with the probe of Oscilloscope as
illustration below. Select channel 2 (>70dB) from the antenna input. Enter D-mode,
select menu6 to adjust RFAGC item until the monitor peak value to 0.8V
3Pf
输入
INPUT
4. Screen & Focus voltage adjustment
Apply pattern signal in normal status, enter D
off the vertical output.
Adjust the SCRREEN switch on the flyback transformer to make a horiz
shining line just visible on the screen.
Turn on the vertical output, adjust the "FOCUS" on the flyback transformer to
obtain the optimum focus.

5. White balance adjustment

1)Apply the black and white pattern in normal status;
2)Alignment of normal color temperature
① Change Color Temperature to normal status
② Use a color analyzer to measure the black side of the screen. By changing the
value of RC, GC and BC, set the reading of the color analyzer to X=285, Y=295.
AGC
Screen & Focus
adjustment
Pincushion correction &
Horizontal
adjustment
IN60
Amplitude
输出
OUTPUT
-mode, press "TV/AV" button to turn
White balance
adjustment
Sub-brightness
adjustment
.
p-p
ontal

Hide quick links: