General Troubleshooting - Chauvet GEYSER P4 User Manual

Table of Contents

Advertisement

General Troubleshooting

Symptom
No output or
low output or
fog machine is
spitting fluid
Circuit breaker or fuse
keeps blowing
Product does not
power up
Product does not
output fog
Page 16 of 19
Display
Possible Cause
Wrong fluid
"Addr" or "HEAT"
Blocked pipes or
failing part
Excessive load on the
circuit
Off
Short circuit along the
power lines
No energy on power
outlet
Loose or damaged
power cord
Off
Blown fuse
Internal problem
No fluid
Heater or pump
clogged
Wired remote
disconnected or
defective
"Addr" or "HEAT"
Inappropriate wired
remote operation
Wireless remote
receiver not
connected
Wireless remote
transmitter ran out of
battery
Internal problem
If you still experience problems after trying the above solutions, contact Chauvet
Technical Support.
Possible Action
Clean thoroughly with CHAUVET® FCQ. For
full instructions, see
Fogger
Maintenance. Refill
with CHAUVET® water-based fog fluid.
Contact Customer Service
Make sure that the total load does not exceed
80% of the breaker or fuse nominal current
Check the power lines and power cords
Check power outlet
Change to another outlet
Check the power cord
Replace blown fuse with a good one of the
same type and rating
Send product for repair
Turn the product off and replenish the fog fluid
(use only CHAUVET® water-based fog fluid)
Clean thoroughly with CHAUVET® FCQ. For
full instructions, see
Fogger
Maintenance. Refill
with CHAUVET® water-based fog fluid.
Make sure that the remote is connected
Try the remote on another Geyser P4 if
available
See
Wireless Remote Control
Make sure that the wireless remote receiver is
connected
Replace battery on wireless remote transmitter
Send the product for repair
Geyser P4. User Manual Rev. 2
for instructions