Outdoor High Temperature Set-point (P.08)
To change the outdoor high temperature set-point:
1. In the Parameter information time mode, use the Up (+) or Down (-) buttons to
select P.08. Then, press the Info button to enter the Outdoor high temperature
set-point mode.
2. In the Outdoor high temperature set-point mode, use the Up (+) or Down (-)
buttons to change the value and press the Info button to set to the desired
mode.
Item
Outdoor high
temperature set-
point
Unavailable
Note
 If no buttons are pressed for 10 seconds or if the Info button is pressed, the
current parameter value will be saved automatically.
 To return to the <PARAMETER INFORMATION MENU MODE>, press the [Reset]
button once.
 If no buttons are pressed for five minutes, the display will automatically return to
the <PARAMETER INFORMATION MENU MODE>.
30
Configuring the NPE-180A/240A Water Heater
Description
 Sets the outdoor high temperature
set-point when outdoor reset is ON
(DIP switch #1 'OFF') (default: 70 ℉
(21 ℃ ))
 Range: 5 ℉ (-15 ℃ ) – 104 ℉ (40 ℃ )
 Cannot be lower than the [Outdoor
low temperature set-point + 9 ℉
(5 ℃ )]