5.4.3 Pump Post Purge Time (P.06)
This function is used to set the post purge time after a combustion cycle is
completed.
To change the pump post purge time:
1. In the Parameter information time mode, use the Up (+) or Down (-) buttons to
select P.06. Then, press the Info button to enter the Pump post purge time mode.
2. In the Pump post purge time mode, use the Up (+) or Down (-) buttons to
change the value and press the Info button to set to the desired mode.
Range
Description
0
Pump post purge time unavailable
Sets the pump post purge time when heating
1 – 120 (sec)
stops in a system (default: 30 sec).
Note
If no buttons are pressed for 10 seconds or if the Info button is pressed, the
current parameter value will be saved automatically.
To return to the <PARAMETER INFORMATION MENU MODE>, press the [Reset]
button once.
If no buttons are pressed for five minutes, the display will automatically return to
the <PARAMETER INFORMATION MENU MODE>.
Configuring the NPE-180A/240A Water Heater
Display
27