Screws; Signal Ground/Protection Ground Jumper Plug - Texas Instruments 880 User Manual

Hide thumbs Also See for 880:
Table of Contents

Advertisement

0.5
CHANGING SIGNAL GROUND /
PROTECTION GROUND
WARNING
Disconnect the power cable before
removing the cover! Failure to
remove the power cable will result
in a serious shock hazard. Chang-
ing the signal ground/protection
ground jumper should only be done
by a qualified technical person.
The Model
880
Printer is normally assembled with
protection ground and signal ground connected
by a jumper plug between E4 and E5 on the Moth-
erboard.
When a system needs the signal-chassis ground
to be isolated, remove the jumper plug between
E4 and E5 and place it between E4 and E3 for
storage.
If you are not sure which configuration to use,
measure the resistance between pins
1
and
7
of
0 0
@
D
E3
E4 .
E5 .
the serial data cable with the cable connected to
the system. If an open circuit is measured, the
jumper plug must be installed between E4 and E5.
If a short circuit is measured, the jumper plug
between E4 and E5 must be removed and installed
between E4 and
E3
for storage. Refer to Figures
0-2and 0-3.
OVERHEAD VIEW
GROUND JUMPER
PLUG LOCATION
SCREWS
SCREWS
- .r--
---,1
2222627-38
Figure 0-2.
Locations of Printer
Cover Screws
2222627-39
Figure 0-3.
Signal Ground/Protection Ground Jumper Plug
0-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

880 dp

Table of Contents