Texas Instruments 880 User Manual page 34

Hide thumbs Also See for 880:
Table of Contents

Advertisement

Table 3-1.
Configuration Codes
Configuration Code*
Definition
Communication
Mode
Selection
(one only)
Baud Rate
(one only)
Parity
Selection
(one only)
National
Language
Version
(one only)
13 Full-duplex modem mode
14 Direct connection mode, pin 11 of serial interface ON for READY
15
Direct connection mode, pin 11 of serial interface OFF for READY
16 Current loop
17 Parallel interface
18 Communications controller interface (if installed)
21
110 bits per second
22
200 bits per second
23
300 bits per second
24
600 bits per second
25
1200 bits per second
26
2400 bits per second
27
4800 bits per second
28
9600 bits per second
2A 19200 bits per second
Data
Parity
Parity
Bits
Bits
Format
31
7
odd
32
7
even
35
7
odd
36
7
even
37
7
1
mark
-38
7
1
space
39
8
0
not used
3A
8
1
odd
3B
8
1
even
41
United States
42 France
43 United Kingdom
44 Germany / Austria
45 Sweden/Finland
46 Denmark/Norway
47 Spain/Latin America
48 Switzerland
49 Canadian French
*Underlined codes are the default codes.
3-12
Received
Bits Checked?
no
no
yes
yes
no
no
no
yes
yes

Hide quick links: