FX communication
1.2

Communication Types

The FX Series supports the following 5 types of communication.
1 ) N:N network
Data transfer with FX
performed on a N:N basis. They can link data of a small-scale system if using this network.
For the system configuration please refer to subsection 1.2.1, specifications refer to chapter
3, wiring refer to chapter 2, settings and the number of transferred data and example
program refer to chapter 4,diagnostics refer to chapter 12.
2 ) Parallel link
Data transfer with FX
performed on a 1:1 basis for 100 auxiliary relays and 10 data registers. With the FX
FX
data transfer is performed for 50 auxiliary relays and 10 data registers.
0N
For the system configuration please refer to subsection 1.2.2, specifications refer to chapter
3, wiring refer to chapter 2, setting and example program refer to chapter 5, diagnostics refer
to chapter 12.
3 ) Computer link (Data transfer using dedicated protocol)
Data transfer with RS-485 (RS-422) units can be performed on a 1:n (16) basis using
dedicated protocol.
For the system configuration please refer to subsection 1.2.3, specifications refer to chapter
3, wiring refer to chapter 2, setting of communication format refer to chapter 6, dedicated
protocol refer to chapter 7 & 8, diagnostics refer to chapter 12.
4 ) No protocol communication (Data transfer using RS instruction)
Data communication with a diversified RS-232C unit including personal computers, bar code
readers and printers can be performed using no protocol communications.
This communication uses RS instruction's or an FX
For the system configuration please refer to subsection 1.2.3, specifications refer to chapter
3, wiring refer to chapter 2, setting of communication format, RS instruction and example
program refer to chapter 6 and 9, diagnostics refer to chapter 12.
When using the RS instruction, for setting the communication format refer to chapter 6, for
the RS instruction and example program please refer to chapter 9. Or when using an FX
232IF, for setting and example program please refer to chapter 10.
5 ) Optional programming port
The port can support programming protocol, if connected to an FX
FX
-232ADP, FX
2NC
FX
Series programmable controller.
1S
For notes on use, refer to chapter 11, diagnostics refer to chapter 12.
, FX
, FX
2N
2NC
1N
, FX
, FX
, FX and FX
2N
2NC
1N
-232-BD, FX
-422-BD and FX
1N
2N
, FX
, FX
programmable controllers can be
1S
0N
programmable controllers can be
2C
-232IF special function block.
2N
-422-BD for the FX
1N
Introduction 1
1S
-232-BD, FX
-232ADP ,
2N
0N
, FX
, FX
2N
2NC
1-2
and
-
2N
,
1N