FX communication
b ) Program of slave station No.1
Counter reset
X001
Master
communication
error
M8183
FNC 12
MOV
FNC 12
MOV
Slave 2
communication
error
M8185
FNC 12
MOV
Counter input
X000
C 1
Slave 2
Contact of
communication
slave 2 C2
error
device
M8185
M1140
FNC 12
MOV
Slave 2
communication
error
M8185
FNC 20
D 0
ADD
RST
C 1
K1M1000 K1Y010
K1X000 K1M1064
K1M1128 K1Y020
C 1
D 1
Y005
M1070
Y006
K 10
D 10
D 20
D 11
END
N:N network 4
Operation 1)
Operation 2)
Operation 3)
Operation 4)
Operation 5)
Operation 6), 8)
Operation 7)