IBM totalstorage 326 User Reference page 164

Network attached storage 300
Hide thumbs Also See for totalstorage 326:
Table of Contents

Advertisement

Table 28. Diagnostic error messages (continued)
Error Code
Meaning
217-XXX-000
Failed BIOS hard disk drive
test
Note: If RAID is configured,
the hard disk drive number
refers to the RAID logical
array.
217-XXX-001
Failed BIOS hard disk drive
test
Note: If RAID is configured,
the hard disk drive number
refers to the RAID logical
array.
217-XXX-002
Failed BIOS hard disk drive
test.
Note: If RAID is configured,
the hard disk drive number
refers to the RAID logical
array
217-XXX-003
Failed BIOS hard disk drive
test
Note: If RAID is configured,
the hard disk drive number
refers to the RAID logical
array.
217-XXX-004
Failed BIOS hard disk drive
test
Note: If RAID is configured,
the hard disk drive number
refers to the RAID logical
array.
217-XXX-005
Failed BIOS Fixed Disk test
Note: If RAID is configured,
the hard disk drive number
refers to the RAID logical
array.
264-XXX-0NN
Failed tape-drive test
264-XXX-999
Errors on multiple tape drives See error messages/text in the PC Doctor error log for
301-XXX-000
Failed Keyboard test
405-XXX-000
Failed Ethernet test on
controller on the system
board
152
Model 326 User's Reference
FRU/action
Hard disk drive 1
Hard disk drive 2
Hard disk drive 3
Hard disk drive 4
Hard disk drive 5
Hard disk drive 6
1. Tape cartridge, if user executed the read/write tape
drive test (XXX = 256)
2. SCSI or power cable connected to tape drive with SCSI ID
NN.
3. Tape drive with SCSI ID NN (Refer to the Help and
Service Information appendix of the tape drive's user
guide).
4. System board or SCSI Controller (Run SCSI controller
diagnostic to determine if the SCSI bus is functioning
correctly.)
detailed information on each individual tape drive error.
Keyboard
1. Verify that Ethernet is not disabled in BIOS
2. System board

Advertisement

Table of Contents
loading

Table of Contents