IBM totalstorage 326 User Reference page 127

Network attached storage 300
Hide thumbs Also See for totalstorage 326:
Table of Contents

Advertisement

Table 21. Storage controller troubleshooting (continued)
Problem indicator
Component
One or more green
Power supply
LEDs off
CRUs
All drive CRUs
Front panel
Battery
Cache active
Host loop
Expansion loop
Possible cause
Possible solutions
Power cord
Make sure that the
unplugged or
power cord is plugged in
switches turned off
and the power-supply
switches are turned on.
Midplane failure
Have the midplane
replaced (service
technician only).
Power supply
Make sure that the cords
problem
are plugged in and
power supplies are
turned on.
Hardware failure
If any other LEDs are on,
replace the midplane
(service technician only).
Battery failure
Replace the battery.
The cache is
1. Use the
disabled, the cache
has failed, battery
failure
2. Replace the RAID
3. Replace the battery.
Host, managed hub,
1. Check if host
or switch is off or
has failed
2. Replace attached
Fibre Channel cable
Ensure that the Fibre
has failed
Channel cables are
undamaged and properly
connected.
GBIC has failed
1. Ensure GBIC is
2. Replace GBIC.
RAID controller has
1. Ensure that the unit
no power or has
failed
2. Replace RAID
Drives are
Ensure that the drives
improperly installed
are properly installed.
or not installed
RAID controller has
1. Ensure that the unit
no power or has
failed
2. Replace the RAID
3542 drive failure
Replace the drive.
Externally attached
1. Replace the drive.
expansion port
2. Replace the
device has failed
Chapter 8. Troubleshooting
storage-management
software to enable
the cache.
controller.
managed hub or
switch is on.
devices that have
failed.
seated properly.
is powered on.
controller.
is powered on.
controller.
expansion unit GBIC
or Fibre Channel
cable.
115

Advertisement

Table of Contents
loading

Table of Contents