York YKKE Series Installation Manual page 12

Mini-split air conditioner dc inverter compact cassette type unit ykke 12 - ykke 18
Table of Contents

Advertisement

Split Type Outdoor Unit
(Refer to Fig 5.4, 5.5 and Table 5.1)
Fig. 5.4
D
Fig. 5.5
Table 5.1: Length Specifications of Split Type Outdoor
Unit (unit: mm/inch)
Outdoor Unit Dimensions
W x H x D
780x540x250 (30.7x21.25x9.85)
760x590x285 (29.9x23.2x11.2)
810x558x310 (31.9x22x12.2)
845x700x320 (33.27x27.5x12.6)
770x555x300 (30.3x21.85x11.81)
800x554x333 (31.5x21.8x13.1)
845x702x363 (33.27x27.6x14.3)
NOTE: The minimum distance between the outdoor
unit and walls described in the installation guide does
not apply to airtight rooms. Be sure to keep the unit
unobstructed in at least two of the three directions (M,
N, P) (See Fig. 5.6)
M
N
Fig. 5.6
Page 12
H
W
A
B
Mounting Dimensions
Distance A
Distance B
549 (21.6)
276 (10.85)
530 (20.85)
290 (11.4)
549 (21.6)
325 (12.8)
560 (22)
335 (13.2)
487 (19.2)
298 (11.73)
514 (20.24)
340 (13.39)
350 (13.8)
540 (21.26)
P
Drain Joint Installation
Before bolting the outdoor unit in place, you must install
the drain joint at the bottom of the unit. (See Fig. 5.7)
1. Fit the rubber seal on the end of the drain joint
that will connect to the outdoor unit.
2. Insert the drain joint into the hole in the base pan
of the unit.
3. Rotate the drain joint 90° until it clicks in place
facing the front of the unit.
4. Connect a drain hose extension (not included) to
the drain joint to redirect water from the unit
during heating mode.
NOTE: Make sure the water drains to a safe location
where it will not cause water damage or a slipping
hazard.
Seal
Drain joint
(A)
Fig. 5.7
Notes On Drilling
Hole In Wall
You must drill a hole in the wall for the refrigerant
piping, and the signal cable that will connect the indoor
and outdoor units.
1. Determine the location of the wall hole based on
the location of the outdoor unit.
2. Using a 65-mm (2.5") core drill, drill a hole in the
wall.
NOTE: When drilling the wall hole, make sure
to avoid wires, plumbing, and other sensitive
components.
3. Place the protective wall cuff in the hole. This
protects the edges of the hole and will help seal it
when you finish the installation process.
Base pan hole of
outdoor unit
Seal
(B)

Advertisement

Table of Contents
loading

Table of Contents