Panasonic SA-AK570PL Servise Manual page 67

Table of Contents

Advertisement

(Product reference value: 3,000±90Hz)
1. Connect a frequency indicator. (Fig 10)
2. Playback the middle portion of the test tape (QZZCWAT).
3. Adjust the motor screw so that the following output level is produced. (Fig 11)
Adjustment Range: 3,000 ± 90Hz (a constant speed)
13.1.5. Bias Voltage Check
1. Connect an electrical voltmeter. (Fig 12) (Fig 9 for location of Test point)
2. Set the function to "TAPE" position.
3. Insert a normal blank cassette tape (QZZCRA).
4. While pressing and holding down [REC (
pressing the buttons till the recording pause mode is activated.)
5. Check that the output level is within the standard range.
Standard Range: 20 ± 3mV
13.1.6. Bias Frequency Check
1. Connect a digital frequency counter (Fig 13).
2. Set the function to "TAPE" position.
3. Insert a normal blank cassette tape (QZZCRA) and press "REC" mode on main unit.
4. Check that the output frequency is within the standard range.
Fig. 10
Fig. 11
)] button, press [TAPE (
Fig. 12
Standard Value: 100 ±8 kHz
Fig. 13
67
)] button to pause the recording mode. (Repeat
SA-AK570PL / SA-AK570GCP

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sa-ak570gcp

Table of Contents