Minimum Alcove Clearance to Combustible Materials
The Regency Freestanding models have been alcove approved and must be installed
with a listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height - 84" (2134mm)
Maximum depth of alcove - 36" (914mm)
Unit
Medium F2402M
with Airmate
with Rear Deflector 15" (381 mm)

Floor Protection

A combustible floor must be protected by non-combustible
material (like tile, concrete board, or certified to UL-1618 or
as defined by local codes) extending beneath the heater and
a minimum of 6" (152mm) from each side and minimum 16"
(406mm) from the front face of the heater and minimum 6"
(152mm) (or the rear clearance to combustibles whichever
is smaller) from the rear of the heater.
When installed with horizontal venting, non-combustible floor
protection must beneath the flue pipe and extend 2" (51mm)
beyond each side.
Minimum Overall Width (X) of Floor
Protector for all installations:
Heater
F2402M
Unit
Medium F2402M
46" (1168 mm)
with Airmate
46" (1168 mm)
with Rear Deflector
*The rear clearance to combustibles is less than 6", for corner installations the rear corners may be angled to take advantage of the closer clearances.
F2400/S2400 Freestanding Woodfire
G
15" (381 mm)
36" (914 mm)
Minimum Overall Depth (y) of Floor Protector
Residential
"C" Vent
Close Clearance
Y
Z
Y
6" (152 mm)
45"*(1143 mm)
6" (152 mm)
45"* (1143 mm)
From
From Flue
Unit
Center-line
H
I
5.5" (139 mm) 27" (685 mm)
6.5" (165 mm)
27" (685 mm)
NOTE: In Canada, floor protection must extend 18" (450mm) to the
front and 8" (200mm) to each side and back of the heater.
Residentiial
Close Clearance
Z
Y
5" (127 mm)
45"*(1143 mm)
5" (127 mm)
45"* (1143 mm)
Min.
Width
J
K
12" (304 mm)
54" (1371 mm)
13" (330 mm)
54" (1371 mm)
Mobile Home
Z
Y
5" (127 mm)
45"*(1143 mm)
5" (127 mm)
45"* (1143 mm)
installation
Min.Hearth
to Rear Wall
L
48" (1219 mm)
49" (1244 mm)
Alcove
Z
5" (127 mm)
5" (127 mm)
9